PRODUCTS
PRODUCTS
Duplex Service Drop - Aluminum Conductor
Duplex Service Drop Wire, its main composition is 1350-H19 aluminum with phase conductors concentrically twisted and PVC or XLPE for insulation. The neutral core is made of concentrically twisted AAC, ACSR, or 6201 aluminum alloy. Mainly used for 120V overhead service applications. Such as street lighting, outdoor lighting, and building temporary services. The voltage between the phases is 600V and below. The conductor temperature of PVC insulated conductors does not exceed 75 °C, and the conductor temperature of XLPE insulated conductors does not exceed 90 °C.
Inquiry
Product description
Product Applications
Duplex Service Drop Wire, its main composition is 1350-H19 aluminum with phase conductors concentrically twisted and PVC or XLPE for insulation. The neutral core is made of concentrically twisted AAC, ACSR, or 6201 aluminum alloy. Mainly used for 120V overhead service applications. Such as street lighting, outdoor lighting, and building temporary services. The voltage between the phases is 600V and below. The conductor temperature of PVC insulated conductors does not exceed 75 °C, and the conductor temperature of XLPE insulated conductors does not exceed 90 °C.
Product Specifications
Duplex service drop cable meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum Conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.
Product Standards
Duplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.
The Diagram of Structure:
2 power cores consisting of standard aluminium conductors, insulated with XLPE insulation
Code Name |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000ft(lbs) |
Rating(Amps) |
||||||
Size AWG |
Strand |
Insulation Thickness (mls) |
Size AWG |
Strand |
Breaking Strength (lbs) |
XLPE |
POLY |
XLPE |
POLY |
|
AAC |
||||||||||
Pekingese |
6 |
Solid |
45 |
6 |
7/w |
563 |
63.5 |
61.7 |
70 |
70 |
Collie |
6 |
7/w |
45 |
6 |
7/w |
563 |
66.8 |
63.1 |
70 |
70 |
Dachshund |
4 |
Solid |
45 |
4 |
7/w |
881 |
95.5 |
93.4 |
90 |
90 |
Spaniel |
4 |
7/w |
45 |
4 |
7/w |
881 |
100.5 |
95.4 |
90 |
90 |
Doberman |
2 |
7/w |
45 |
2 |
7/w |
1,350 |
152.7 |
145.7 |
120 |
120 |
Malemute |
1/0 |
19/w |
60 |
1/0 |
7/w |
1,990 |
242.6 |
234.2 |
160 |
160 |
Code Name |
Phase Conductor |
Bare Neutral Messenger |
Weight Per 1000ft(lbs) |
Rating(Amps) |
||||||
Size AWG |
Strand |
Insulation Thickness (mls) |
Size AWG |
Strand |
Breaking Strength (lbs) |
XLPE |
POLY |
XLPE |
POLY |
|
ACSR NEUTRAL-MESSENGER |
||||||||||
Setter |
6 |
Solid |
45 |
6 |
6/1 |
1,190 |
75.0 |
73.2 |
70 |
70 |
Shepherd |
6 |
7/w |
45 |
6 |
6/1 |
1,190 |
78.3 |
74.6 |
70 |
70 |
Eskimo |
4 |
Solid |
45 |
4 |
6/1 |
1,860 |
113.7 |
111.6 |
90 |
90 |
Terrier |
4 |
7/w |
45 |
4 |
6/1 |
1,860 |
118.7 |
113.6 |
90 |
90 |
Chow |
2 |
7/w |
45 |
2 |
6/1 |
2,850 |
181.7 |
174.7 |
120 |
120 |
Bull |
1/0 |
19/w |
60 |
1/0 |
6/1 |
4,380 |
288.7 |
280.3 |
160 |
160 |
6201 ALLOY NEUTRAL-MESSENGER |
||||||||||
Chihuaha |
6 |
Solid |
45 |
6 |
7/w |
1,110 |
67.6 |
65.8 |
70 |
70 |
Vizsla |
6 |
7/w |
45 |
6 |
7/w |
1,110 |
70.9 |
67.2 |
70 |
70 |
Harrier |
4 |
Solid |
45 |
4 |
7/w |
1,760 |
102.0 |
99.9 |
90 |
90 |
Whippet |
4 |
7/w |
45 |
4 |
7/w |
1760 |
107.0 |
101.9 |
90 |
90 |
Schnauzer |
2 |
7/w |
45 |
2 |
7/w |
2,800 |
163.3 |
156.2 |
120 |
120 |
Heeler |
1/0 |
19/w |
60 |
1/0 |
7/w |
4,460 |
259.2 |
250.8 |
160 |
160 |