PRODUCTS


+
  • 40.jpg
  • 39.jpg
  • 41.jpg

Welding Cable

The cable can be used in the connectors of electric weld and pliers of the electric welding whose toward earth voltage of the low voltage is not more than A.C.200V and the pulsant D.C.peak value is 400V,the long-time permissible working temperature of cable is not more than 65°C.


Inquiry

Product description

Product Application

The cable can be used in the connectors of electric weld and pliers of the electric welding whose toward earth voltage of the low voltage is not more than A.C.200V and the pulsant D.C.peak value is 400V,the long-time permissible working temperature of cable is not more than 65°C.

Product Specifications
450/750 Flexible Copper/CCA Rubber Insulation Electric Welding Cable
450/750 PVC insulation CCA welding cable 
voltage AC 200V~DC 400V 
Standards: IEC60245

Model,Names and Work In the Temperature(See Table 1)

Model Name Working Temperature of Core≤(oC)
YH Natural Rubber Sheath for Welding Cable 65
YHF Horoprene Rubber or Other Syntheitic Sheath Welding Cable 65

Product Standard

The welding cable can be produced according to the standard GB5013.6-60245 IEC81.

Name and IEC Standard :

(1). Rubber Sheathed Welding Cable 245 IEC 81

(2). Rubber Sheathed Welding Cable 245 IEC 82, which is made of chloroperene or the composite stretchy materials.

Conductor Materials: Copper, Tinned Copper or CCA

Jacket: Rubber or PVC

Specifications,Size,Weight and Technical Data(See Table 2)

Conductor Nominal Section (mm2) Conductive Core Thickness of Section Sheath (mm) Average Outer Diameter (mm) 20oC Conductor Resistance≤ (Ω/km) Reference Weight(kg/km)
Number/Diameter of Core(mm) Min Max YH YHF
10 322/0.20 1.8 7.5 9.7 1.91 146 153.51
16 513/0.20 2.0 9.2 11.5 1.16 218.9 230.44
25 798/0.20 2.0 10.5 13.0 0.758 316.6 331.15
35 1121/0.20 2.0 11.5 14.5 0.536 426 439.87
50 1596/0.20 2.2 13.5 17.0 0.379 592.47 610.55
70 2214/0.20 2.4 15.0 19.5 0.268 790 817.52
95 2997/0.20 2.6 17.0 22.0 0.198 1066.17 1102.97
120 1702/0.30 2.8 19.0 24.0 0.161 1348.25 1392.55
150 2135/0.30 3.0 21.0 27.0 0.129 1678.5 1698.72
185 1443/0.40 3.2 22.0 29.0 0.106 1983.8 2020.74

Delivery Requirements

If cable is packed in circle,its length should be 100m long.If it is packed in bundle,its length should be no less than 100m.The short cable which are no less than 20m are permissible to delivery.The quantity of short cable should be no more than 10% of the whole delivery.If mutual agreement is made,everything will be done according to the agreement.