YJV POWER CABLE
The PVC insulated power cable are suitable for fixed laying in power transmission and distribution lines with A.C.50HZ and voltage rating of up to or including 6KV. The product has the characteristics of low halogen (or halogen-free), low smoke, corrosion resistance, anti-rat ant, waterproof and UV protection.
Inquiry
Product description
Product Application:
The PVC insulated power cable are suitable for fixed laying in power transmission and distribution lines with A.C.50HZ and voltage rating of up to or including 6KV. The product has the characteristics of low halogen (or halogen-free), low smoke, corrosion resistance, anti-rat ant, waterproof and UV protection. Rail transit 1500V and below DC traction power cables are suitable for urban traffic subways or DC power areas with high safety and reliability requirements.
Special structural design can be carried out according to the product use environment.
Product Performance:
1.The long-term permissible operation temperature of the conductor shall not be higher than 70℃
2. Conductor maximum short circuit((less then 5 second) temperature shall not be higher than 160℃
3. The cable is not limited by drop in level when being laid, and the environment temperature shall not be lower than 0℃
4. Perfect chemical stability, resistant against acids, alkalis, grease and organic solvents, and flame retardance
5. Light weight, perfect bending properties, installed and maintained easily and conveniently
6. Rated voltage: 0.6/1kV, 3.6/6kV
7.Conductors:Copper or Aluminum
8. Number of cores: One, two, three, four, five
Product Structure:
Copper(or aluminium)conducting core
PVC insulation
Non-woven cloth wrapped inner bedding material layer
Double steel tape(steel wire)armoured layer
PVC or PE outer sheath
Mica tape insulation
We can produced it according to IEC60502 and IEC60331,and the product can be produced against the standard of BS, DIN, or other standard according to customers’ requirement.
Type | Name | Usage |
VV | PVC insulated PVC sheathed power cable | Can be laid at indoor, tunnel and tube. Cable cannot under take mechanism outside force |
VLV | ||
VY | PVC insulated and PE sheathed power cable |
Can be laid at indoor, tunnel tube and serious polluted places. Cablecannot undertake mechanism outside force |
VLY | ||
VV22 | PVC insulated steel belt armored and PVC sheathed power cable |
Can be laid at indoor, tunnel tube and mining well. Cable cannot undertake mechanism outside force |
VLV22 | ||
VV23 | PVC insulated steel belt armored and PE sheathed power cable |
Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force |
VLV23 | ||
VV32 | PVC insulated steel belt armored and PE sheathed power cable |
Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force |
VLV32 | ||
VV33 | PVC insulated steel belt armored and PE sheathed power cable |
Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force |
VLV33 | ||
VV42 | PVC insulated steel belt armored and PE sheathed power cable |
Can be laid at indoor, tunnel tube mining well and serious polluted places. Cable cannot undertake mechanism outside force |
VLV42 | ||
VV43 | PVC insulated steel belt armored and PE sheathed power cable |