ACSR Aluminium Transmission Conductor Steel Reinforced ASTM B232

ACSR conductor have been widely used in power transmission lines with various voltage levels,because they have such good characteristics as simple structure,convenient installation and maintenance,low cost large transmission capacity.And they are also suitable for laying across rivers and valleys where special geographical features exist.


Inquiry

Product description

Product Applications

ACSR cable is a kind of aluminum stranded wire with steel core, which has simple structure, convenient erection and maintenance, low line cost, large transmission capacity, and is convenient for laying across special geographical conditions such as rivers and valleys. It has good electrical conductivity and sufficient mechanical strength. It has the characteristics of high strength, high tensile strength, and the distance between towers and rods can be enlarged. Therefore, it is widely used in overhead transmission and distribution lines of various voltage levels.

Product Specification

(1) all aluminium conductor (AAC)

(2) all aluminimum alloy conductor(AAAC)

(3) aluminum conductor steel reinforced (ACSR)

(4) anti-corrosion type ACSR

(5) aluminimum conductor aluminimum clad steel reinforced(ACSR/AW)

(6)aluminimum conductor aluminimum alloy reinforced(ACAR)

Product Standard

We can supply this conductor according to different recognized standards, such as IEC61089, BS215, BS EN 50182: 2001, STM B231, CSA C49, DIN480201, JIS C3109, customer special specification also can be satisfied.

ACSR or ACSR cable or ACSR conductor used for Overhead electrical distribution and transmission lines for distributing power.

(AAAC) Conductor as per ASTM-B-399-1992

(AAAC) Conductor as per BS-3242-1970

(AAAC) Conductor IS: 398-IV-1994

(ACSR) as per ASTM-B-233-1992

(AAC) as per BS-215-1-1970

(AAC) as per IS-398-1: 1976

(AAC) as per ASTM-B-231-1990

(ACSR) as per IS: 398-II: 1976 & IS: 398-V: 1992

(ACSR) BS-215-II-1970

(AACSR) as per IEC-1089-1191

AAC(All aluminum conductor) are suited for overhead power line.

Aluminum Conductor Steel Reinforced is in accordance with BS215-2-70.

Nominal Area

(mm2)

Stranding Wire No.and Dia.

(No./mm)

Calculated Area(mm2)

Approx

Overall Dia.

(mm)

ApproxWeight

(kg/km)

Calculated Min.Breaking Load

(KN)

Calculated D C Resistance at 20oC

(Ω/km)

Code Name

 

Al.

St.

Al.

St.

Total.

20

6/2.11

1/2.11

20.98

3.50

24.48

6.33

84.85

7.90

1.368

Squirrel

25

6/2.36

1/2.36

26.24

4.37

30.62

7.08

106.10

9.61

1.0930

Gopher

30

6/2.59

1/2.59

31.61

5.27

36.88

7.77

127.80

11.45

0.9077

Weael

40

6/3.00

1/3.00

42.41

7.07

49.48

9.00

171.50

15.20

0.6766

Ferret

50

6/3.35

1/3.35

52.88

8.81

61.70

10.05

213.80

18.35

0.5426

Rabbit

60

6/3.66

1/3.66

63.12

10.52

73.64

10.98

255.30

21.77

0.4546

Mink

60

12/2.59

7/2.59

63.23

36.88

100.10

12.95

463.60

52.94

0.4566

Skunk

70

12/2.79

7/2.79

73.37

42.80

116.20

13.95

538.10

61.20

0.3936

Horse

70

6/4.09

1/4.09

78.84

13.14

91.98

12.27

318.90

27.05

0.3639

Raccon

100

6/4.72

7/1.57

105.00

13.55

118.50

14.15

394.30

32.70

0.2733

Dog

150

30/2.59

7/2.59

158.10

36.88

194.90

18.13

725.70

69.20

0.1828

Wolf

150

18/3.35

1/3.35

158.70

8.81

167.50

16.75

505.70

35.70

0.1815

Dingo

175

30/2.79

7/2.79

183.40

42.80

226.20

19.53

842.40

79.80

0.1576

Lynx

175

18/3.61

1/3.61

184.30

10.24

194.50

18.05

587.60

41.10

0.1563

Caracal

200

30/3.00

7/3.00

212.10

49.48

261.50

21.00

973.80

92.25

0.1363

Panther

200

18/3.86

1/3.86

210.60

11.70

222.30

19.30

671.40

46.55

0.1367

Jaguar

250

30/3.35

7/3.35

264.40

61.70

326.10

23.45

1214.00

111.40

0.1093

Bear

300

30/3.71

7/3.71

324.30

75.67

400.00

25.97

1489.00

135.70

0.08912

Goat

300

18/4.78

7/1.68

323.10

15.52

338.60

24.16

1012.00

69.64

0.08914

Batang

350

54/3.00

7/3.00

371.70

49.48

431.20

27.00

1443.00

120.70

0.07572

Bison

400

54/3.18

7/3.18

428.90

55.59

484.50

28.62

1022.00

131.90

0.06741

Zebra

450

30/4.50

7/4.50

447.00

111.30

588.30

31.50

2190.00

198.30

0.06057

EIK

450

54/3.35

7/3.35

476.00

61.70

537.30

30.15

1800.00

146.20

0.06074

Camel

10

6/1.50

1/1.50

10.62

1.77

12.39

4.50

43

4.13

2.7060

Mole

35

6/2.79

1/2.79

36.66

6.11

42.77

8.37

149

13.17

0.7822

Fox

75

6/3.39

1/3.39

75.00

12.50

87.50

11.97

304

25.76

0.3825

Beaver

85

6/4.22

1/4.22

83.94

13.99

97.93

12.66

339

28.80

0.3419

Otter

95

6/4.50

1/4.50

95.40

15.90

111.30

13.50

386

32.70

0.3007

Cat

105

6/4.72

1/4.72

14.16

17.50

105.00

14.16

424

35.90

0.2733

Hare

105

7/4.39

7/1.93

105.95

20.48

126.43

14.57

450

41.00

0.2702

Hyena

130

6/5.28

7/1.75

131.37

16.84

148.21

15.81

492

40.80

0.2184

Leopard

130

26/2.54

7/1.91

131.74

20.06

131.74

15.89

520

46.30

0.2191

Coyote

130

18/3.05

1/3.05

131.58

7.31

138.89

15.25

419

30.00

0.2190

Couqar

130

30/2.36

7/2.36

131.22

30.62

161.84

16.52

602

58.00

0.2202

Tiger

240

30/3.18

7/3.18

238.30

55.60

293.90

22.26

1094

100.50

0.1213

Lion

528

54/3.53

7/3.35

528.50

68.50

597.00

31.77

1996

161.00

0.0547

Moose

Notes:

Resistance is calculated using ASTM standard increments of stranding and metal conductivity of 61.2% IACS for EC (1350) and 8% IACS for steel. AC (60Hz) resistance includes current dependent hysteresis loss factor for 1 and 3 layer constructions.

Current ratings are based on 75℃ conductor temperature, 25℃ ambient, 2ft/s wind, 96/watts/sq. Ft sun, 0.5 coefficients of emissivity and absorption.