PRODUCTS


+
  • 37.jpg
  • 31.jpg
  • 36.jpg

Duplex Service Drop Wire

Duplex Service Drop Wire, its main composition is 1350-H19 aluminum with phase conductors concentrically twisted and PVC or XLPE for insulation. The neutral core is made of concentrically twisted AAC, ACSR, or 6201 aluminum alloy. Mainly used for 120V overhead service applications. Such as street lighting, outdoor lighting, and building temporary services. The voltage between the phases is 600V and below. The conductor temperature of PVC insulated conductors does not exceed 75 °C, and the conductor temperature of XLPE insulated conductors does not exceed 90 °C.


Inquiry

Product description

Product Applications

Duplex Service Drop Wire, its main composition is 1350-H19 aluminum with phase conductors concentrically twisted and PVC or XLPE for insulation. The neutral core is made of concentrically twisted AAC, ACSR, or 6201 aluminum alloy. Mainly used for 120V overhead service applications. Such as street lighting, outdoor lighting, and building temporary services. The voltage between the phases is 600V and below. The conductor temperature of PVC insulated conductors does not exceed 75 °C, and the conductor temperature of XLPE insulated conductors does not exceed 90 °C.

Product Specifications
Duplex service drop cable meets or exceeds the following ASTM specifications:
B-230 Aluminum Wire, 1350-H19 for Electrical Purposes.
B-231 Aluminum Conductors, Concentric-Lay-Stranded.
B-232 Aluminum Conductors, Concentric-Lay-Stranded, Coated Steel Reinforced (ACSR).
B-399 Concentric-Lay-Stranded 6201-T81 Aluminum Alloy Conductors.
B-901 Compressed Round Stranded Aluminum Conductors Using Single Input Wire.

Product Standards
Duplex service drop cable meets or exceeds all applicable requirements of ANSI/ICEA S-76-474.

Product Parameter

Code Name

Phase Conductor

Bare Neutral Messenger

Weight Per 1000ft(lbs)

Rating(Amps)

Size AWG

Strand

Insulation Thickness

(mls)

Size AWG

Strand

Breaking Strength

(lbs)

XLPE

POLY

XLPE

POLY

AAC

Pekingese

6

Solid

45

6

7/w

563

63.5

61.7

70

70

Collie

6

7/w

45

6

7/w

563

66.8

63.1

70

70

Dachshund

4

Solid

45

4

7/w

881

95.5

93.4

90

90

Spaniel

4

7/w

45

4

7/w

881

100.5

95.4

90

90

Doberman

2

7/w

45

2

7/w

1,350

152.7

145.7

120

120

Malemute

1/0

19/w

60

1/0

7/w

1,990

242.6

234.2

160

160

 

Code Name

Phase Conductor

Bare Neutral Messenger

Weight Per 1000ft(lbs)

Rating(Amps)

Size AWG

Strand

Insulation Thickness

(mls)

Size AWG

Strand

Breaking Strength

(lbs)

XLPE

POLY

XLPE

POLY

ACSR NEUTRAL-MESSENGER

Setter

6

Solid

45

6

6/1

1,190

75.0

73.2

70

70

Shepherd

6

7/w

45

6

6/1

1,190

78.3

74.6

70

70

Eskimo

4

Solid

45

4

6/1

1,860

113.7

111.6

90

90

Terrier

4

7/w

45

4

6/1

1,860

118.7

113.6

90

90

Chow

2

7/w

45

2

6/1

2,850

181.7

174.7

120

120

Bull

1/0

19/w

60

1/0

6/1

4,380

288.7

280.3

160

160

6201 ALLOY NEUTRAL-MESSENGER

Chihuaha

6

Solid

45

6

7/w

1,110

67.6

65.8

70

70

Vizsla

6

7/w

45

6

7/w

1,110

70.9

67.2

70

70

Harrier

4

Solid

45

4

7/w

1,760

102.0

99.9

90

90

Whippet

4

7/w

45

4

7/w

1760

107.0

101.9

90

90

Schnauzer

2

7/w

45

2

7/w

2,800

163.3

156.2

120

120

Heeler

1/0

19/w

60

1/0

7/w

4,460

259.2

250.8

160

160

Advantages conventional overhead bundled cables:
1. Relatively unaffected by short circuits caused by external forces, such as high winds, and falling tree branches, unless they scratch the insulation layer.

2. Can be installed close to trees or buildings, and will not generate sparks when touched.
3. Easier installation, no need for crossbars and insulators. It is also easy to install the hanging wire, less labor intensive, and requires fewer construction resources.
4. Significantly improves the safety of workers working on live conductors.

What is the purpose of bundled conductors?

The purpose of bundled conductors is designed so that the reactance of the transmission line can be reduced.

And it also reduces the voltage gradient, corona loss, radio interference, and surge impedance of the transmission line.

 

ONLINE FEEDBACK